Little programming is needed as the default settings work in most cases.
Installer Programming
Enter Installer Programming by pressing NEXT/DOWN simultaneously and holding for five seconds. (The NEXT button is second from the left.) Choose or accept:
TYPE= AIR CYCLE FILTER
AIR RELEASE TIME = 4.0 MINUTES.
BACKWASH = 14 MINUTES. Can be shortened for treatment of odor only in clean water.
AIR CHARGE TIME = 40. In most cases it’s best to leave it at default.
RINSE TIME = OFF. Must stay at OFF.
GALLONS CAPACITY=1,000 Gal.
REGEN = DELAYED. This delays regeneration until the REGENERATION TIME you select.
RELAY 1, RELAY 2, SERVICE ALARM = OFF
User Programming
Next go to the user programming cycle by pressing NEXT/UP simultaneously and holding until the screen changes.
DAY OVERRIDE = 2 is best in most cases.
REGENERATION TIME: Set time for regeneration. If you have a water softener or another backwashing filter, be sure their regeneration times don’t overlap. Allow at least an hour for this filter to complete its regeneration.
LIGHT NORMALLY= OFF