Instructional Videos from Pentair Water University: Fleck 5600 & 2510 Valves
Fleck 5600
Fleck 5600 Control Valve Tear Down: https://youtu.be/BeD7IdE0FB8
Uses:
- Troubleshooting parts on the 5600 mechanical and SXT valves.
- Determining what color and size replacement parts you need for your specific valve type.
- Determining where replacement parts go.
- This video covers replacement of seals and spacers and piston, plus the examination and/or replacement of the brine valve (softeners only), the injector assembly (softeners only), and drain line flow control. The instructional video is done with a mechanical meter softener valve (Econominder) but can be generalized to any 5600 control.
Special Notes: Seals and spacer replacement using the stuffer tool begins at 7:00 minutes. The job is often done without the use of the stuffer tool.
Fleck 5600 Air in Brine System: https://youtu.be/c923S1j-Zbc
Use to check for air entering a brine system and check for damaged fittings or hose:
- When there is low to no salt usage by softener,
- The service water is “hard”,
- There are visible leaks, or
- Experiencing water hammering, or hydraulic shock, during regeneration
- This video covers the connections and tubing in the brine draw system from the valve body to the air check in the brine tank. A Fleck 5810 is used in the demo, but all other Fleck controls work exactly the same.
Fleck 5600 Brine Valve Repair and Replacement: https://youtu.be/MiJktBgvi38
Use when:
- There is salty service water,
- The brine tank is overfilling, or
- There is excessive salt use
- This video covers inspection and/or replacement of the brine valve. The 5600 mechanical meter softener valve (Econominder) is used in the demo, but it can be generalized to other Fleck controls.
Fleck 5600 Injector Repairs: https://youtu.be/Rq3JR0FNkwE
Clean or replace a clogged injector or screen when:
- The brine tank is overfilling,
- No soft water to home, or
- There is salty service water
Fleck 5600 Drain Hose: https://youtu.be/M2vt85Bb6Yk
Diagnose and clear an obstructed drain hose when:
- The pressure drops in the home,
- There is salty service water, or
- There is slow to no drain flow during service regeneration
Fleck 5600 Meter Repairs: https://youtu.be/NWjjC__66xc
Meter not registering flow when there is:
- No regeneration
- No salt use
- No capacity decline on the control, or
- No flow indicator on the display
Depressurize Fleck 5600 Valve: https://youtu.be/iYHXHVD5ik8
Depressurize a system before completing any service work.
Set Time on Fleck 5600 Controller: https://youtu.be/NTp-Qm4j9y0
Use when the:
- Regeneration cycle occurs at the wrong time
- Display shows the wrong time
____________________________________________________________________________
Fleck 2510
Fleck 2510 Control Valve Tear Down: https://youtu.be/9kGhqrbt_R0
Uses:
- Troubleshooting parts on the 5600 mechanical and SXT valves
- Determining what color and size replacement parts you need for your specific valve type
- Determining where replacement parts go
Seals and spacers replacement begins at 9:20 on the video.
Fleck 2510 Air in Brine System: https://youtu.be/wY9oSSCD9E4
Use when air might be the brine system due to:
- Low to no salt usage
- Hard service water
- Visible leaks, or
- Water hammering during a regeneration
Fleck 2510 Brine Valve Repair and Replacement: https://youtu.be/x3Zp_OR5f6M
Use when:
- There is salty service water,
- The brine tank is overfilling, or
- There is excessive salt use
Fleck 2510 Injector Repair: https://youtu.be/Cbfp2cEKx_c
Clean or replace a clogged injector or screen when:
- Water overfills the brine tank
- There is no soft water, or
- There is salty service water
Fleck 2510 Drain Hose: https://youtu.be/1B6Gj2xHrkw
Diagnose and clear an obstructed drain hose when:
- Pressure drops in the home
- Service water is salty, or
- There is slow to no drain flow during regeneration
Fleck 2510 Meter Repairs: https://youtu.be/rD-2acNxW4Y
Use when there is:
- No regeneration
- No salt use
- No capacity decline on the control, or
- No flow indicator on the display
Depressurize Fleck 2510 System: https://youtu.be/9I8UYps_tSA
Depressurize a system before completing any service work.